Levelflex FMP53
Guided radar level measurement for the highest hygiene requirements in the food and life sciences industry
General Information
Input / Output
Electrical Data
Mechanical Data
Certification / Approvals
Additional Information
SKU: FMP53
Highlights
- Process connections: For hygiene requirements (Tri-Clamp, 11851, 11864, NEUMO,
- Varivent N, SMS)
- Temperature: -20 to +150°C (-4 to +302°F)
- Pressure: -1 to +16bar (-14.5 to +232psi)
- Maximum measuring range: Rod 6m (20ft)
- Accuracy: ±2mm (0.12")
- International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, 5-point linearity protocol
Fields of application
- Food & Beverage
- Life Science
- Utilities
Details
Levelflex FMP53 for continuous level measurement for hygienically sensitive applications in the food and life sciences industry. FMP53 meets the hygiene requirements according to ASME BPE and USP Class VI. The unique in situ validation without dismantling from the process is a cost saving advantage. FMP53 guided radar offers maximum reliability even in case of moved surface and foam, for changing medias and in case of filling via spray head.
We find the right product for you
Downloads
Questions & Answers