Metri IC-LTM Turbine Flow Meter

Rugged and accurate industrial in-line turbine flow meter for the volumetric flow measurement of liquids

Metri Measurements
SKU: IC-LTM

Highlights

  • Type of medium: Liquids
  • Measuring range: 0.4 to 9166 l/min
  • Accuracy: ± 0.25 % o.r.
  • Process pressure range: up to 1400 bar
  • Process temperature range: -196 to 350 °C
  • ATEX approval

Fields of application

  • Chemicals
  • Power Generation
  • Oil & Gas
  • Marine & Offshore
  • Water & Wastewater

Details

The Metri IC-LTM Turbine Flow Meter is an industrial in-line turbine flow meter that provides accurate and reliable measurement of a range of extreme pressure and temperature applications. It has a versatile configuration, high accuracy and when combined with its low cost of ownership it’s easy to see why the LTM is a highly popular choice for many uses.


We find the right product for you
What do our customers say

Somya Gupta

The conversation was highly helpful to me. I want to know about the suitable sensors that can be used for level measurements for conical tank systems. Mr. Pedro has quickly responded and explained in very ease way. It was nice interacting with him.

Questions & Answers

Good afternoon, I’m interested by your METRI IC-LTM Turbine Flowmeter. It will be mounted on helicopter for flight test instrumentation purpose. The maximum operational flow range is 50 l/min. We need the “IC-MV-PO pulse output module” instrument to connect it to our acquisition module. The preselected model order code is : “IC-LTM-016B-S-S-A-B-S-0-P-R-0”. One little concern: the pulse output module operating temperature range is -10°C to 55°C so it will not be possible to install this module inside the sensor area (higher temperatures expected). In this case we foresee to install this module in the helicopter cabin zone. I need to understand if the cable from sensor to pulse output module can be “cut” to go from sensor area to cabin zone. So, is there a connector on sensor part (no integral cable) ? Is it an option ? If no, what is the maximum cable length between sensor and instrument ? 3m as mentioned in the datasheet? Same questions for the pulse output module : Is there a connector for sensor input ? And for the module output, is there a connector (no integral cable) ? If no, what is the maximum cable length between instrument and our acquisition module ? Thank you in advance for your answers. Best regards, Fawzi Janoudi (Safran Engineering Services) FTI System Architect On Board & Testing Business Unit Safran Data Systems 5, avenue des Andes - CS 90101 91978 Courtaboeuf Cedex, France (1 answer)
by Fawzi Janoudi, 11 months ago
Fawzi, thank you for contacting Visaya. You are right for high temperature application remote version needs to be chosen (the code you selected is correct). The maximal length between sensor with coil output and IC-MV-PO (pulse output module) is 3 meters. The cable will be attached to sensor and it is connected via terminal block, alternatively with PCB plug or 4-pin M12 connector. Regarding the cable between instrument and acquisition module, there is no limitation on the cable length.
by Da/Visaya, 10 months ago