High-temperature electromagnetic flow meter for process applications with a compact, easily accessible transmitter

Our expert

Luis Arcos will help you to find the right product: +49 (0)30 509 308 800

Contact Expert
Endress+Hauser
SKU: Promag P 300

Highlights

  • Measuring range: 4 dm³/min to 9600 m³/h (1 to 44000 gal/min)
  • Accuracy: Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
  • Suitable for fluids producing buildup and for abrasive fluids e.g. potter's clay, lime milk, ore slurry
  • Process temperature from –40 to 180 °C (–40 to 365 °F)
  • Hazardous area, hygienic, material, marine, metrological approvals and certificates

Fields of application

  • Applications in the Chemical industry
  • For abrasive fluids (e.g. potter's clay, lime milk, ore slurry)
  • For fluids producing buildup (e.g. wastewater sludge)
  • Process applications with corrosive liquids and high medium temperatures

Details

The Proline Promag P 300 is dedicated to chemical and process applications with corrosive liquids and highest medium temperatures. With its compact transmitter Promag P 300 offers a high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology ensures compliance and process safety at all times.


General Information
More Information
Measuring principle Electromagnetic
Measured variablesVolume flow, Conductivity, Mass flow,Corrected volume flow
Medium typeLiquid
Flow rate liquid (volumetric flow)4 dm³/min to 9600 m³/h 1 to 44 000 gal/min
Recommended velocityOptimum velocity: 2 to 3 m/s (6.56 to 9.84 ft/s) For abrasive fluids, v < 2 m/s (6.56 ft/s) For fluids producing buildup, v > 2 m/s (6.56 ft/s)
Min. conductivity≥ 5 μS/cm
Maximum error % liquid (volumetric flow)Standard: ±0.5 % o.r. ± 1 mm/s (0.04 in/s) Optional: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Display type4‐line backlit display
Remote display available
Response timeStatus input: Configurable, 5 to 200 ms
Modbus RS485: typically 25 to 50 ms
Process temperature range-20 to 150 °C (-4 to 302 °F) for PFA
-20 to 180 °C (-4 to 356 °F) for PFA high-temperature
-40 to 130 °C (-40 to 266 °F) for PTFE
Maximum allowable pressurePN 40, Class 300, 20K
Input/Output
More Information
InputsStatus input
4...20 mA input
Output3 outputs:
4...20 mA HART (active/passive)
4...20 mA WirelessHART
4...20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Communication protocolHART
PROFIBUS DP
PROFIBUS PA
FOUNDATION Fieldbus
Modbus RS485
Profinet
Ethernet/IP
OPC-UA
ResolutionCurrent input 0/4…20 mA: 1 µA
Current output 0/4...20 mA/ Ex i : 0.38 µA
Mechanical Data
More Information
Process connectionDN 15 to 600 (½ to 24"), pressure ratings PN 6/10/16/25/40, Class 150/300, JIS 10K/20K, AS 2129 Table E
Flange typeEN (DIN), ASME, JIS, AS
Nominal diameter rangeDN 15 to 600 (½ to 24")
Inlet run≥ 5 × DN
Outlet run≥ 2 × DN
Wetted materialLiner: PFA; PTFE
Electrodes: 316L; Alloy C22; 2.4602; Tantalum; Platinum; Titanium; Duplex 1.4462
Electrode material316L; Alloy C22; 2.4602; Tantalum; Platinum; Titanium; Duplex 1.4462
Tube materialStainless steel, 1.4301/304/1.4306/304L
Housing materialAluminum AlSi10Mg, coated Stainless steel, 1.4404
Degree of protectionStandard: IP66/67, Type 4X enclosure
Option: IP69
Surface roughnessElectrodes ≤ 0.3 to 0.5 µm (11.8 to 19.7 µin)
Liner with PFA ≤ 0.4 µm (15.7 µin)
Electrical Data
More Information
Voltage TypeAC/DC
Power supply24 V DC
100 to 230 V AC
100 to 230 V AC / 24 V DC
Current consumptionTransmitter: Max. 400 mA (24 V) & Max. 200 mA (110 V, 50/60 Hz; 230 V, 50/60 Hz)
Cable entryCable gland: M20 × 1.5
Thread for cable entry: NPT ½", G ½" & M20
Device plug for digital communication: M12
Certification/Approvals
More Information
Hazardous approvalsATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC
Hygienic / Drinking water approvalsACS, NSF 61
Other Approvals/ CertificationCE, C-tick, EAC
Metrological approvals and certificates
LR approval, DNV GL approval, ABS approval
PED, CRN
3.1 Certificate
Additional Information
More Information
Ambient temperature rangeFlange material carbon steel: -10 to 60 °C (14 to 140 °F)
Flange material stainless steel: -40 to 60 °C (-40 to 140 °F)
Storage temperatureThe storage temperature corresponds to the operating temperature range of the transmitter and the sensor Transmitter (standard): -40 to 60 °C (-40 to 140 °F) Flange material carbon steel: -10 to 60 °C (14 to 140 °F) Flange material stainless steel: -4
Mounting typeCompact/ Remote display
Shock resistanceYes
Vibration resistanceYes
Reverse polarity protectionYes (FOUNDATION Fieldbus & PROFIBUS PA)
Galvanic isolationYes
Electromagnetic compatibility (EMC)As per IEC/EN 61326 (NE 21)
PROFIBUS DP: Emission limits as per EN 50170 Volume 2, IEC 61784
Our expert

Luis Arcos will help you to find the right product: +49 (0)30 509 308 800

Contact Expert
  • 30-day return policy
  • Official reseller
  • Expert engineering support
  • Free delivery in the EU

Questions & Answers

from €2,394.43 plus VAT
Shipping in 14 working days
+ 1 day delivery to Germany
Loading...
  • 30-day return policy
  • Official reseller
  • Expert engineering support
  • Free delivery in the EU
Product Details