Radar or pressure transmitter?
Nowadays, I see a lot of recommendations to use radar for level measurement. Would it benefit me to switch from a pressure transmitter to a radar level meter? ...
Volume measurement from pressure transmitter
I have a pressure device installed for level measurement, and now the operator wants to receive data on the tank volume. Can I do that using the pressure device? ...
Micro Motion 1700 output
Help! I tried to set up the 1700, but the output isn't working properly and I can't access the device with the handheld. We managed the basic configuration from the front display. Locally the device works fine, but the output doesn't reach my control system, which means the process values don't eith ...
Level calculation for pressure transmitter with capillary
I have a level transmitter with capillary, and I need to do the level calculation. The transmitter is one meter below the takeoff point, and the tank's takeoff point is five meters. The product's specific gravity is 0.89, and the capillary is filled with glycol at a specific gravity of 1.02. How can ...
How to connect a pressure transmitter and HART communicator
Hi. I have a question about HART communicators and devices. Can you help? How do I connect a pressure transmitter with a HART communicator? ...
Reliable steam measurement?
What's the best technology to measure high-pressure steam flow? I want a flow meter with high accuracy, reliability, long lifespan, and low cost if possible. Also, is there a portable instrument for measuring steam? ...
Level transmitter calibration!
I'd like to know more about calibration of level transmitters. Do we really need to calibrate these devices? ...
Emerson 5300 GWR and sludge!
We have an Emerson 5300 GWR LT! Sometimes, the level fluctuates severely. After we open and inspect the chamber, we find the rod clean but sludge in the chamber drain. After flushing the chamber, the level goes back to normal. How does this sludge cause this problem when the rod itself is clean? Can ...
Critical instruments? Plant asset management
Should we schedule replacement for our critical valve accessories (like solenoid valves and limit switches) and critical process transmitters according to their projected lifespan? ...
Endress+Hauser FMP51 output signal
Hi. We have an E+H Levelflex FMP51. The output is not changing proportionally with the level, and we already checked the output in the control room for different currents. We simulated the output from the transmitter function menu and transmitter responded, and all other related parameters checked o ...